The Anatomy of Verified Value
– A Proprietary Framework by Aurema Group LLC —
In a market where speculation has eclipsed the substance, the real value has become invisible. Physical assets—buildings, vessels, infrastructures—are treated as mere numbers on a spreadsheet, ignoring their history, physical state and latent risks.
This lack of rigor is not a technical mistake. It’s an ethical gap.
Prop Trust Verified® is born of three decades of experience as a Judicial Perito in real conflicts: where a bad tile generated a structural failure, where a clause hidden in a maritime title annulled an investment of millions, and where the absence of a physical inspection cost more than the asset itself.
This document is not a commercial proposal. It’s a working protocol. A standard we invite the industry to adhere to.
It’s not enough with a drone photo. We require human presence, calibrated instrumentation and validated methodologies in courts (ISO 17020).
• Structural inspection with ultrasounds and thermogram
• Evaluation according to UNE 41100 (edifices) and IMO A.1023(26) (nival)
• Report signed by collegiate judicial expert
The record title is only the beginning. We analyze:
• Procurement and unregistered servitudes
• zoning and licensing conflicts
• Accident history (IMO GISIS) for naval assets
• Validation with 12 public and private databases
We create a digital twin (BIM + GIS) that integrates historical data, maintenance and sensors in real time.
• Verifiable model in blockchain (SHA-256 + Ethereum TX)
• Update every 90 days
• Dashboard for investor with risk map
Collection of primary documentation and definition of the scope of inspection.
Multidisciplinary team (civil expert, naval and architect) on site. Includes topographic measurement, mapping review and interviews.
Analysis of 7 layers of ownership and legal risk. Report with probability matrix (Alta/Media/Baja).
Generation of virtual twin and load on secure platform. Access to the investor with interactive dashboard.
Emission of certificate Prop Trust Verified®with digital signature of the expert and seal of Aurema Group LLC. Validity: 12 months.
Challenge: Clean title, but unregistered servitude and moisture damage.
Solution: Termography revealed leaks; municipal archive discovered a sentence of 1952.
Outcome: Price reduction in 22% and extended warranty clause.
Challenge: Complete documentation, but hidden repairs after breakdown.
Solution: Ultrasounds revealed defective welding; IMO GISIS showed 3 unreported incidents.
Outcome: Operation suspended. Saving: €3.2M.
Challenge: Permission in force, but conflict with POT not detected.
Solution: Georeference revealed overlap with hydrological protection zone.
Outcome: Renegotiation of the price and guarantee of regulatory compliance.
Regulation (EU) 2023/1114 requires:
Aurema structure SPVs in Spain under Law 19/1992 and Circular 5/2022 of the BdE.
FSRA recognizes judicial experts as part of due diligence.
Take care of:
We work with local firms for broadcasting in ADGM Digital Asset Platform.
For accredited investors (Rule 506(c)) it is required:
Our report is designed to meet “material fact disclosure” standards.
“The buyer has the right to suspend payment until delivery of the certificate Prop Trust Verified®, emitido por un perito judicial colegiado. En caso de discrepancia, se nombrará un árbitro técnico independiente.”
STS 123/2021: Reconoce validez de informes periciales en disputas constructivas.
TSJ CV 456/2022: Nulidad relativa por omisión de servidumbres no inscritas.
TS 2023/789: Tokenización requiere verificación previa por experto independiente.
| Norma | Ámbito | Vigencia | Requisito Clave |
|---|---|---|---|
| CTE DB SE-A | Estructuras | 2023 | Resistencia sísmica y durabilidad mínima de 50 años |
| UNE 41100 | Inspección estructural | 2022 | Métodos no destructivos obligatorios en edificios > 30 años |
| ISO 17020 | Peritaje técnico | 2021 | Requisitos para organismos de inspección independientes |
| Norma | Órgano | Aplicación |
|---|---|---|
| IMO Resolution A.1023(26) | Organización Marítima Internacional | Inspección técnica de buques > 24m |
| LR Rules for Ships | Lloyd’s Register | Certificación de clase y mantenimiento |
| IGF Code | IMO | Seguridad en buques con combustibles alternativos |
Nuestros modelos no son estimaciones subjetivas. Son fórmulas validadas en sentencias judiciales y ajustadas a la realidad física y jurídica del activo.
Vₐ = Vₘ × (1 − Df) × (1 − Rj)
Donde:
Ejemplo real (Edificio Valencia, 2024):
Vₘ = €4.2M → Df = 0.18 (grietas + humedad) → Rj = 0.12 (servidumbre no inscrita) → Vₐ = €3.28M
Modelo basado en deterioro acelerado (UNE 41100 + ISO 15927):
Tᵣ = T₀ × [1 − (C / Cₘ)ⁿ]
Donde:
Caso Buque “María Luisa”:
T₀ = 30 años → C/Cₘ = 0.78 → n = 1.5 → Tᵣ = 14.2 años (vs. 22 años declarados)
Basado en datos de 127 casos judiciales (2020–2025):
| Tipo de Fallo | Coste Medio (% Vₘ) | Desviación Estándar |
|---|---|---|
| Grieta estructural > 0.3mm | 8.2% | ±2.1% |
| Corrosión en chapa naval > 2mm | 14.7% | ±3.4% |
| Servidumbre no inscrita (riesgo legal) | 6.5% | ±1.8% |
Este protocolo debe ser seguido por todo equipo de inspección de Aurema Group. Cualquier desviación debe justificarse por escrito y firmarse por el Perito Responsable.
El informe preliminar debe contener:
Nota: El informe final se emite tras revisión por segundo perito y firma del responsable.
Cuando dos peritos emiten conclusiones opuestas sobre un mismo activo, Aurema Group aplica el siguiente protocolo, validado en 14 arbitrajes técnicos (2021–2026).
“En caso de discrepancia entre peritos, las partes designarán un Árbitro Técnico independiente, colegiado y con ≥15 años de experiencia en el ámbito relevante (edificación, naval o infraestructura). El árbitro dispondrá de 10 días hábiles para emitir su dictamen, vinculante para ambas partes.”
Ejemplo real (Arbitraje Madrid, 2025):
Dos peritos discreparon en la vida útil de un puente. El árbitro (Prof. Dr. L. Martínez, ETSI Caminos) aplicó el modelo Tᵣ y concluyó: “Vida útil restante: 18.3 años (IC 95%: 16.1–20.5)”. La sentencia del Juzgado de lo Mercantil nº 8 dio por válido el dictamen y resolvió la disputa en 7 días.
Selecciona tu perfil para conectar con el equipo adecuado
Complete sus datos